Transverse-stress limit for irreversible degradation of Nb_3Sn cables · revision history
Revision 1
Superseded · first revision · record
- Title
- Transverse-stress limit for irreversible degradation of Nb3Sn cables
- Plain
- Nb3Sn is brittle, and the huge magnetic forces in a high-field magnet squeeze the cable until its ability to carry current is permanently damaged; where that threshold lies and what breaks first is uncertain.
- Precise
- Rutherford cables of Nb3Sn filaments in epoxy-impregnated coils at fields up to $\sim 1.6e5\,\mathrm{G}$ are under transverse stress of order $1.5e9 \text{ to } 2e9\,\mathrm{dyn}/\mathrm{cm}^{2}$ (approximate). Determine the stress at which the critical current degrades irreversibly, its dependence on filament layout, impregnation and temperature cycling, and the microscopic failure mode (filament cracking, void collapse, debonding), as a function that fixes the maximal practical dipole field.
- Settled by
- Critical-current measurements of cable stacks under calibrated transverse stress, combined with post-test microscopy of filament cracks and a model that reproduces the onset stress.
- Kind
- well-posed
- Answer type
- value
- References
- (empty)
- Literature status
- open
- Status note
- (empty)
- Posed since
- (empty)