Microdosimetry of alpha emitters with mobile daughters · revision history
Revision 1
Accepted · first revision · record
- Title
- Microdosimetry of $\alpha$ emitters with mobile daughters
- Plain
- Alpha-emitting drugs release a chain of short-lived radioactive descendants, which can break free of the carrier molecule and travel elsewhere in the body before decaying. Where that dose ends up is not known.
- Precise
- Determine the absorbed dose at cellular scale from Ac-225 and Ra-223 chains, including recoil-induced release of daughters (Fr-221, Bi-213, Pb-209 for Ac-225) and their redistribution, given alpha ranges of 40 to 100 micron and hit numbers of order a few per cell nucleus. An answer is a microdosimetric specific-energy distribution per organ and tumour, with measured daughter redistribution fractions.
- Settled by
- Direct measurement of daughter biodistribution combined with stochastic microdosimetric calculation validated by cellular damage endpoints.
- Kind
- well-posed
- Answer type
- value
- References
- (empty)
- Literature status
- open
- Status note
- Daughter redistribution, particularly to kidney and bone marrow, was recognized but not quantified in patients as of 2025.
- Posed since
- 2010